SPS 210 PUMP2

Automatic operation correct
Y
Manual operation correct
Y
Current reading - Red
24.2
Current reading - White
23.9
Current reading - Blue
24.1
Run hour reading
Na
Any interlocks operational
Y
PLC input/output operational
Y
SCADA feedback operational
Y
Perform a manual trip to test fault conditions
Y

Motor Tag

  • Site-Motor-Pump 2

SPS 210 PUMP1

Automatic operation correct
Y
Manual operation correct
Y
Current reading - Red
23.2
Current reading - White
23.5
Current reading - Blue
23.4
Run hour reading
N
Any interlocks operational
Y
PLC input/output operational
Y
SCADA feedback operational
Y
Perform a manual trip to test fault conditions
Y

Motor Tag

  • Site-Motor-Pump 1

SPS207 PUMP1

Automatic operation correct
Y
Manual operation correct
Y
Current reading - Red
4.2
Current reading - White
4.5
Current reading - Blue
4.3
Run hour reading
643.95
Any interlocks operational
Y
PLC input/output operational
Y
SCADA feedback operational
Y
Perform a manual trip to test fault conditions
Y

Motor Tag

  • Site-Motor-Pump 1

SPS321 PUMP2

Automatic operation correct
Y
Manual operation correct
Y
Current reading - Red
13.5
Current reading - White
13.8
Current reading - Blue
13.4
Run hour reading
Na
Any interlocks operational
Y
PLC input/output operational
Y
SCADA feedback operational
Y
Perform a manual trip to test fault conditions
Y

Motor Tag

  • Site-Motor-Pump 2

SPS321 PUMP1

Automatic operation correct
Y
Manual operation correct
Y
Current reading - Red
9.9
Current reading - White
9.7
Current reading - Blue
9.8
Run hour reading
Na
Any interlocks operational
Y
PLC input/output operational
Y
SCADA feedback operational
Y
Perform a manual trip to test fault conditions
Y

Motor Tag

  • Site-Motor-Pump 1

SPS310 pump 2

Automatic operation correct
Y
Manual operation correct
Y
Current reading - Red
23.9
Current reading - White
23.5
Current reading - Blue
23.4
Run hour reading
Na
Any interlocks operational
Y
PLC input/output operational
Y
SCADA feedback operational
Y
Perform a manual trip to test fault conditions
Y

Motor Tag

  • Site-Motor-Pump 2

SPs310 pump 1

Automatic operation correct
Y
Manual operation correct
Y
Current reading - Red
25.5
Current reading - White
25.1
Current reading - Blue
24.9
Run hour reading
Na
Any interlocks operational
Y
PLC input/output operational
Y
SCADA feedback operational
Y
Perform a manual trip to test fault conditions
Y

Motor Tag

  • Site-Motor-Pump 1

SPS314 pump 2

Automatic operation correct
Y
Manual operation correct
Y
Current reading - Red
3.7
Current reading - White
3.6
Current reading - Blue
3.7
Run hour reading
Na
Any interlocks operational
Y
PLC input/output operational
Y
SCADA feedback operational
Y
Perform a manual trip to test fault conditions
Y

Motor Tag

  • Site-Motor

SPs314 pump 1

Automatic operation correct
Y
Manual operation correct
Y
Current reading - Red
4.0
Current reading - White
3.9
Current reading - Blue
3.9
Run hour reading
Na
Any interlocks operational
Y
PLC input/output operational
Y
SCADA feedback operational
Y
Perform a manual trip to test fault conditions
Y

Motor Tag

  • Site-Motor-Pump 1

SPS311 pump 2

Automatic operation correct
Y
Manual operation correct
Y
Current reading - Red
10.3
Current reading - White
10.6
Current reading - Blue
9.9
Run hour reading
8844
Any interlocks operational
Y
PLC input/output operational
Y
SCADA feedback operational
Y
Perform a manual trip to test fault conditions
Na- insulation resistance U-E 999 ohm, V-E 999 MOHM, W-E 999 M OHM -

Motor Tag

  • Site-Motor-Pump 2